Purpose

Site visit for SLS Electric to assess electrical service installation project, take measurements, and provide updated quote for 200A service plus generator options.

Contractor Information

  • Company: SLS Electric LLC
  • Contact: Steve
  • Email: steve@slselectric.net
  • Phone: +1 (248) 840-8399
  • Address: 9939 Clarabella Rd, Clare, MI
  • Website: slselectric.net

Background

Phone Call — December 1, 2025:

  • Discussed 200A wire and panel installation options
  • Reviewed generator options:
    • Permanent standby generators (Generac-style) with automatic transfer switch
    • Large portable units with 50A connection (~$3,000 Harbor Freight unit mentioned)
  • Steve will provide two separate quotes:
    1. Electrical service installation (200A)
    2. Generator add-on options

Agenda

  • Walk property and show trench route from house to garage
  • Show existing 2” PVC conduit installed through garage foundation (4 conduits available)
  • Review house main panel (200A, SW corner basement)
  • Take measurements for wire run
  • Discuss 200A wire capacity / 100A initial connection strategy
  • Review generator options in detail:
    • Permanent standby (Generac) — interlock location, transfer switch
    • Portable generator connection — inlet box location, interlock
    • Powering garage only vs. garage + house
  • Discuss timeline and availability

Documents to Have Ready

Key Specifications to Confirm

  • Wire: 200A capacity (2/0 AWG copper or 4/0 AWG aluminum)
  • House breaker: 100A at existing 200A panel
  • Garage panel: 200A main breaker, 40+ circuits
  • Distance: ~60-80 feet underground
  • Conduit: 2” PVC already installed through foundation (4 conduits, long-radius bends)

Generator Discussion Points

Based on phone call, Steve will discuss:

Option 1: Permanent Standby Generator (Generac-style)

  • Automatic transfer switch
  • Natural gas connection (already planned for boiler)
  • Whole-house backup capability
  • Higher cost but automatic operation

Option 2: Large Portable Generator

  • Manual transfer / interlock
  • 50A connection (NEMA 14-50 inlet)
  • Harbor Freight unit mentioned (~$3,000)
  • Lower cost, manual operation during outages

Key Questions:

  • Where should interlock be installed? (house panel vs. garage panel)
  • Can generator at garage power both garage AND house?
  • What’s the cost difference between options?
  • Natural gas quick-connect for portable generator?

Timing Note

This site visit is scheduled for the same day framing starts (Dec 2-3, 2025). Framing crew (Hershberger’s) will also be on-site.

Comparison Context

Other quotes/visits:

  • Seiter Electric: $4,600 (200A service, 42-space panel, permit included)
  • Mr Electric: Site visit scheduled Dec 8
  • Axiom Wiring: Quote requested, awaiting response

Weather

Weather:

Notes

Quote Details

Electrical Service (200A):

  • Quote Amount:
  • Scope:
  • Timeline:

Generator Add-On:

  • Option 1 (Permanent Standby):
  • Option 2 (Portable Connection):

Decisions

Action Items

  • Compare SLS quote to Seiter Electric ($4,600) when received
  • Review generator options and decide on approach
  • Follow up if quote not received within 3-5 business days after visit